BRXGS - C-1445 CLEAR PRIMER

  • MSDS: BRXGS
  • Manufacturer: CHEMIONICS CORP
  • Product Name: C-1445 CLEAR PRIMER
  • National Stock Number: 6850-00F029851
Product Identification

Product ID:C-1445 CLEAR PRIMER
MSDS Date:01/01/1992
FSC:6850
NIIN:00F029851
MSDS Number: BRXGS

Responsible Party
CHEMIONICS CORP
390 MONROE FALLS RD
TALLMADGE, OH 44278
US

Emergency Phone: 216-733-8834

Info Phone: 216-733-8834/216-733-0086

Cage: 0JVY4

Contractor
CHEMIONICS CORP
TALLMADGE, OH 44278 US

Telephone: 216-733-8834/216-733-0086

Cage: 0JVY4

Ingredients

BUTANOL, N-BUTYL ALCOHOL, PROPYL CARBINOL, BUTYL ALCOHOL

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 2%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TOLUENE

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 21%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


2-BUTANONE (METHYL ETHYL KETONE) (MEK)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 50%

OSHA PEL 200 PPM

ACGIH TLV: 590 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CELLOSOLVE (2-ETHOXYETHANOL), DOWANOL EE, ETHYLENE GLYCOL

CAS: 110-80-5

RTECS: KK8050000

Fraction By Weight: 10%

OSHA PEL 200 PPM

ACGIH TLV: 18 MG/CUM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: LUNG IRRITATION. EYES:
IRRITATION. SKIN: IRRITATION, DERMATITIS, ABSORPTION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES/SKIN/LUNGS: IRRITATION.
Medical Cond Aggravated by Exposure:SKIN DISORDERS

First Aid

First Aid:EYES: FLUSH W/WATER. SKIN: WASH W/SOAP & WATER. INHALATION:
REMOVE TO FRESH AIR. INGESTION: INDUCE VOMITING. OBTAIN MEDICAL
ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING & USE SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:VAPORS MAY TRAVEL ALONG THE GROUND & BE
IGNITED BY AN IGNITION SOURCE AT DISTANT LOCATIONS.

Accidental Release

Spill Release Procedures:DIKE UP TO LIMIT SPREADING. SCRAPE UP OR
ABSORB W/INERT MATERIAL. DON'T FLUSH DOWN SEWER.

Handling

Handling and Storage Precautions:AVOID EXCESS HEAT. AVOID EYE & SKIN
CONTACT.

Exposure Controls

Respiratory Protection:SELF CONTAINED BREATHING APPARATUS UNDER EXTREME
CONDITIONS.
Ventilation:REQUIRED DURING FUSION TO PREVENT EMPLOYEE EXPOSURE TO
VAPORS.
Protective Gloves:IMPERMEABLE
Eye Protection:GOGGLES
Work Hygienic Practices:NORMAL CLEANLINESS SHOULD BE OBSERVED.
Supplemental Safety and Health

Chemical Properties

Spec Gravity:0.9
Solubility in Water:INSOLUBLE
Appearance and Odor:LIQUID; SWEETISH ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
WATER
Stability Condition to Avoid:EXTREME HEAT
Hazardous Decomposition Products:CO2, CO, HYDROGEN CHLORIDE, OTHERS
POSSIBLE.

Disposal

Waste Disposal Methods:DISPOSAL BY INCINERATION IN COMPLIANCE W/LOCAL,
STATE, & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.